CONTROL SYSTEM: A fully programmable logic microprocessor with non-volatile memory provides a user interface through a liquid crystal alphanumeric display. All set points are adjustable by one multi-function interface key pad. The standard control includes: Fully programmable ramp soak functions, product and air temperature display selectable for Fahrenheit or Centigrade scale, alarm/temperature logging, system mode indicator heating/cooling, high/low audible/visual alarms, real time clock, power failure alarm, sensor failure alarms,
service prompts and user password entry system. The modular system includes expansion slots on the control board for the ability to add at a later date, the option of humidification, dehumidification, lighting, RS485 serial
communication interface with capabilities for operation or monitoring of the entire system via a host computer.

CONSTRUCTION: Heavy duty double wall construction.
Interior and exterior finish of heavy gauge steel painted
with white scratch resistant baked enamel. Complete
cabinet and door are insulated and sealed with 100% UL
Class 1 rigid polyurethane foam insulation. The foamedin-
place insulation provides low heat transfer, improved
cabinet performance and prohibits moisture from
migrating into the cabinet walls. Hardware includes:
Heavy duty self closing door hinges, full length stainless
steel pull handle, full peripheral high temperature door
gasket providing a tight seal. Key lock door and 4" casters
for ease of rolling. Complete perimeter anti-condensate
door heater wire thermostatically controlled for
energy savings. The 30 cu. ft. model includes 3 stainless
shelves and an interior drain for user conveyance. The
21, 48 and 76 cu. ft. models include 3 plated wire
shelves per door.

CONDITIONING SYSTEM: Precision control is
provided by the uniform distribution of air through a full
length rear plenum. The plenum delivers conditioned air
evenly throughout the chamber providing
maximum uniformity and efficiency. A heavy duty
refrigeration system provides rapid removal of heat
caused by door openings or product load. The system
accurately delivers cooling based on demand and
modulates the system to provide precision control. The
system utilizes environmentally safe non-toxic CFC free
refrigerant, with air-cooled, hermetically sealed
compressor backed by a 5 year warranty. The system
includes an expansion valve system to optimize capacity
and efficiency. Heating is provided by a stainless sheath
heater, proportionally controlled to ensure precision
temperature uniformity. The complete cabinet is UL and
C-UL listed.

 

General Specifications
STABILITY CHAMBERS
MODEL NO. CU. FT TEMPERATURE RANGE INTERIOR DIMENSIONS, INCHES, (CM) W x F-B x H EXTERIOR DIMENSIONS, INCHES (CM) W x F-B x H

SCN4-24

24 4° to 70°C

23.5" x 30" x 59"
(60 x 76 x 150)

27.5" x 35.5" x 81.5"
(70 x 90 x 207)

SCN4-33

33 4° to 70°C

27.75" x 31" x 67"
(70 x 78 x 170)

31.75" x 35.87" x88.5"
(80 x 91 x 224)

SCN4-52

52 4° to 70°C

51" x 30" x 59"
(129 x 76 x 150)

55" x 35.5" x 81.5"
(139 x 90 x 207)

SCN4-80

80

4° to 70°C

78.5" x 30" x 59"
(199 x 76 x 150)

82.5" x 35.5" x 81.5"
(209 x 90 x 207)

HUMIDITY STABILITY CHAMBERS

HCN4-24

24 4° to 70°C

23.5" x 30" x 59"
(60 x 76 x 150)

27.5" x 35.5" x 81.5"
(70 x 90 x 207)

HCN4-33

33 4° to 70°C

27.75" x 31" x 67"
(70 x 78 x 170)

31.75" x 35.87" x88.5"
(80 x 91 x 224)

HCN4-52

52 4° to 70°C

51" x 30" x 59"
(129 x 76 x 150)

55" x 35.5" x 81.5"
(139 x 90 x 207)

HCN4-80

80

4° to 70°C

78.5" x 30" x 59"
(199 x 76 x 150)

82.5" x 35.5" x 81.5"
(209 x 90 x 207)